Instruments Introduction and analysis service  

       We offer the following analysis services with the help of a variety of precise instruments (shown as below):

Service Item

1.Chemical analysis

2.ICP-AES analysis

3.AAS analysis

4.X-ray fluorescence spectrometry analysis

5.IC analysis

6.Tadioactive chemical analysis

7. α-ray energy spectrometry analysis and γ-ray energy spectrometry analysis

8. X-ray diffraction analysis  

Instruments

High resolution inductively coupled plasma mass spectrometerHR-ICP-MS

Inductively coupled plasma atomic emission spectrometerICP-AES

Atomic absorption spectrometerAAS

X-ray fluorescence spectrometer

X-ray diffractometer

Ion chromatorgraph

High-purity germaniumγspectrometer

Atomic fluorescence spectrometer

 

High resolution inductively coupled plasma mass spectrometerHR-ICP-MS

High resolution inductively coupled plasma mass spectrometer(HR-ICP-MS)

Instrument model:  VG Axiom SC

IntroductionThis instrument is up to date of double focus high resolution inductively coupled plasma mass spectrometer in the world. It can be used to determine content and isotope ratio of trace and ultra-trace element and radioactivity nuclide in the water, metal material, high-purity metal, chemical production, chemical reagent, rock, mineral, soil, plant, animal sample. Detection limit is 10-9~10-12 g/g, the relative standard deviation (RSD) is less than 5%. The relative standard deviation is 0.01~0.1% in the determination of isotope ratio.

back to  top

Inductively coupled plasma atomic emission spectrometerICP-AES  

Inductively coupled plasma atomic emission spectrometer(ICP-AES)

Instrument model: TJA IRIS AP

Introduction: This instrument is equipped late-model solid states detector (CID). It can be used to multi-element determine simultaneity. It can be used to determine content of major and trace element in the water, metal material, high-purity metal, chemical production, chemical reagent, rock, mineral, soil, plant, animal sample. Detection limit is 10-7 g/g, the relative standard deviation (RSD) is less than 3%.

back to  top  

Atomic absorption spectrometerAAS

Atomic absorption spectrometer(AAS)

Instrument model: Hitachi Z5000

Introduction: This instrument is equipped flame and graphite furnace atomizer. It can be used to determine content of major, trace and ultra-trace element in the water, metal material, high-purity metal, chemical production, chemical reagent, rock, mineral, soil, plant, animal sample. Detection limit is 10-6 g/gflame atomizerand 10-9 g/ggraphite furnace atomizer, the relative standard deviation (RSD) is less than 5%.

  back to  top

X-ray fluorescence spectrometer  

Instrument model:  ARL  ADVANTXP  

X-ray fluorescence spectrometer

Introduction: This instrument is equipped Uniquant 5.12 analytical software. It can be used to approximately quantitatively standardless determine seventy elements for the most sample. It is fit to analysis of complexity matrix or without standard material sample. It is can be used to quantitatively determine content of major and trace element in the water, metal material, high-purity metal, chemical production, chemical reagent, rock, mineral, soil, plant, animal sample. Detection limit is 10-6 g/g, the relative standard deviation (RSD) is less than 1%.

back to  top  

X-ray diffractometer

Instrument model: ARL  XTRA  

X-ray diffractometer

Introduction: This instrument is equipped vertical θ wide range goniometer and solid states detector (Peltier detector). It can be used to qualitatively or quantitatively phase analysis and crystal structure determination for the inorganic powder sample.

  back to  top

Ion chromatorgraph  

Instrument model: Dionex Dx 600  

Ion chromatorgraph

Introduction: This instrument can be used to quantitatively determine content of trace and ultra-trace anion and cation in the water, chemical production, chemical reagent, rock, mineral, soil sample. Detection limit is 10-9 g/g, the relative standard deviation (RSD) is less than 5%.

back to  top

High-purity germaniumγspectrometer

Instrument model: ORTEC GMX-50220-S

Introduction: This instrument is can be used to quantitatively determine content of radioactivity nuclide (for example, 235U238U232Th60Co137Cs90Sr) in the water, metal material, chemical production, rock, mineral, soil, plant, animal sample.

back to  top

Atomic fluorescence spectrometer

Instrument model: Haiguang AFS-230E

Introduction: This instrument can be used to quantitatively determine content of trace and ultra-trace AsPbBiHgSnSbTeSeGeCd and Zn in the water, metal material, high-purity metal, chemical production, chemical reagent, rock, mineral, soil, plant, animal sample. Detection limit is 10-9~10-12 g/g, the relative standard deviation (RSD) is less than 10%. 